Data centre & large-load grid connection studies
Large new loads — hyperscale data centres, hydrogen electrolysers and heavy industry — connect at sizes that move voltages, fault levels and power quality on the networks around them. We run the connection and compliance studies that show a large load can be accommodated, and on what terms.
When this study is needed.
- A single load or campus is large enough relative to the local network to affect voltage, thermal loading or fault level at the connection point.
- The connection is power-electronic-heavy — UPS, rectifiers, variable-speed drives or on-site converters — raising harmonic, flicker and power-quality questions.
- A network operator requires evidence for a demand connection: load flow, short-circuit, harmonic, voltage-step and protection coordination.
- On-site generation, battery storage or back-up plant must be modelled alongside the load for islanding, ride-through and reactive support.
How we approach it.
- Agree the load profile, ramp and phasing, the point of connection, and the connection requirements that apply.
- Build the network model — load flow and short-circuit — with the large load and any on-site generation or storage represented.
- Assess steady-state impact: voltages, thermal loading, fault-level headroom and reactive-power / voltage control.
- Assess power quality — harmonic distortion, voltage flicker and voltage steps against the relevant limits — and add EMT where converters or fast dynamics govern.
- Document the connection terms, any reinforcement or mitigation, and the evidence in the form the operator expects.
Tools we use.
- PowerFactory and PSS®E for load flow, fault level and harmonics
- PSCAD / EMTDC for EMT where converter behaviour or fast dynamics matter
- Scripted automation for scenario sweeps and post-processing
Scenarios & operating points.
- Minimum and maximum demand, with credible ramp and phasing of the load
- Range of network strengths, outage conditions and dispatch
- Harmonic and flicker assessment across operating modes
- On-site generation / storage in and out of service, including back-up transfer
What you receive.
- Validated network model files and a model-quality statement
- Load-flow, fault-level, harmonic and power-quality results with interpretation
- A connection assessment: terms, headroom, and any reinforcement or mitigation
- A written report suitable for independent review by the network operator
Evidence that stands up to review.
Every conclusion is traceable to a validated model and a documented scenario. We record tool versions, model sources and assumptions so the work can be reproduced and challenged — the standard a network operator's review expects.
Comparable experience.
Case-study write-ups for this service are in preparation. To discuss directly relevant project experience, brief us — we can talk it through, under NDA where appropriate.
Questions engineers ask.
What counts as a large load for these studies?
Why do data centres need harmonic and power-quality studies?
Can you study the load together with on-site generation or storage?
Brief us on a connection.
Send a one-paragraph scope — the load, the connection point, and the question you need answered. We typically reply within two working days.
Related: Consultancy hub · Grid-code compliance studies · PSCAD / EMT studies · LumiMerse
Skip the form — email the team directly.